  9017 Class I&II Division 2 Z-Purge Control System
  Division 2 purge control
 
Our Price: $895.00


Product Code: DDD-9017


Description Extended Information
 
The "Z" Purge Control System is FM Approved Class I & II, Division 2 Group B-G. Completely  Pre-Assembled for Easy Installation with Short Purge Time (Less Than 2 Minutes per Cubic Foot) and Low Internal Pressure, this Purge Control System includes a Built-In Vent Valve with Spark Arrestor, a Built-In Flow Meter and Pressure Gauge for Easy Set-Up and Operation.

 

The concept of preventing the ignition of flammable elements in a hazardous area using a purge system per NFPA 496 is actually very simple, though its implementation is somewhat more complex. The basic idea in purging electronic equipment is to keep electronics that have the potential of producing sparks or high temperatures separate from the explosive elements. This is accomplished by placing the electronics in an enclosure that is sealed against the entry of the outside atmosphere.

 

To ensure that none of the external atmosphere is within the enclosure, the purge system starts by replacing the internal atmosphere with four volumes of inert gas, supplied via a compressed air or compressed nitrogen line. Only after this purge has occurred are electrical supplies and signals connected to the inside of the enclosure. Because no enclosure can be perfectly sealed, after the purge is complete the purge system must ensure that no exchange of gases can occur. This is accomplished by maintaining a slight positive pressure within the enclosure. If this positive pressure falls below a preset level, the electrical supplies and signals are disconnected from the inside of the enclosure.

 

In Division 2 areas, where explosive elements are only present under abnormal conditions, the connecting and disconnecting of the electrical supply and signals is controlled by the operator. The purge system must provide an indication to the operator in the event of the loss of pressurization. This can be accomplished via an included indicator or a system connected to alarm contacts. The purge process itself is also manual.

 

In Division 1 areas, where explosive elements can reasonably be expected to be present under normal conditions, the entire process must be automatically controlled by the purge system. The purge system controls the purge and automatically disconnects the electrical supply and signals upon loss of internal pressure. Alarm contacts are also provided to alert the user.
 

Accessories for this product...
9026 Pac Seal Connection Kit
Our Price: $70.00
Add
9047 Air Connection Kit
Our Price: $220.00
Add

Related Products...
Articulating Suspension Arm
Our Price: $2,200.00
Add
adjust to nearly any viewing angle
Intrinsically Safe TuffPoint Mouse
Our Price: $545.00
Add
Intrinsically Safe TuffPoint Mouse
9047 Air Connection Kit
Our Price: $220.00
Add
9026 Pac Seal Connection Kit
Our Price: $70.00
Add
9040/9050 Series Industrial Pointing Devices
Call us For Pricing!
Add
9040/9050 Series Industrial Pointing Devices


 Share your knowledge of this product with other customers... Be the first to write a review.



Browse for more products in the same category as this item:

Computer Accessories


1071-Ex Intrinsically Safe Ultrasonic Wall Thickness Gauge $3,340.00
4520KP Series Non-Incendive PC
Ex-PMR 2000 - Intrinsically-Safe Professional Mobile Radio $1,074.00
Lite-Ex HD10 Intrinsically Safe Rubber Cased Flashlight $80.00
AE Light AEX25-EP Intrinsically Safe Flashlight $456.25
i.roc 627 FM Class 1 Div. 1 $3,546.00
i.roc 620 -Ex - Industrial PDA ATEX Zone 1 Gas and Dust Certified $3,546.00
ISL 200-Ex & ISL 400-Ex - Explosion Protected Inspection Lamp
i.roc 420 Ruggedized PDA + 1 GB $2,460.00