Definitions

 

 

 

Intrinsically-Safe Continuity Tester


The EX-DT12 Intrinsically-Safe continuity tester is a handy and robust testing device for use in potentially explosive areas.

The electronics are housed in the test probe, which means the basic device does not have to be handled during measuring and leaves both hands free for the test operation.

 

Intrinsically Safe Continuity Tester

Intrinsically Safe Continuity Tester

The combination of optical and acoustic readout permits usage in a loud environment.

Certifications:

Certification:

II 2 G EEx ia IIC T4

Certificate of Conformity:

TÜV 03 ATEX 2120

Intrinsically Safe PDFData Sheet

Intrinsically Safe PDFManual

Intrinsically Safe PDFCertificate

Ordering Information:

 

Visit This Product at www.ReliabilityDirectStore.com for Pricing and Ordering

 

Specifications:

Working temperature:

-20 ... +50C

Resistance:

10 - 500k

Inductivity test:

10mH – ex-limits

Capacity test:

0.5F – ex-limits

Diode test:

2 diode sections

Max. external inductivity:

1H

Max. external capacity:

1000F

Max. error output flow:

5mA

Max. error output voltage:

3.3V

Max. external voltage resistance outside of ex-zone:

Um = 420V

Duration of operation:

approx. 20h (continuous)

Visual readout:

4 x LED (in test probe)

Acoustic readout:

loudspeaker

Test probe dimensions:

50 x 180 mm (l x )

Overall length:

170 mm (test probe to test probe)

Weight:

approx. 200g (including batteries)

Power supply:

2 x LR03 to IEC