Intrinsically-Safe Mini Non-Contact Infrared Thermometer


For non-contact temperature measurement and monitoring of temperature processes in hazardous areas.

  • High accuracy

  • Simple operation

  • Quick response time

  • Laser target sighting

  • Temperature range: from -18°C to +260°C

  • Battery type: Standard 9V Block

  • Weight: 200g

  • Dimensions: 152 x 101 x 38mm

Intrinsically Safe Non-Contact Infrared Thermometer

The intrinsically-safe non-contact temperature measuring equipment Ex-MP 4 is a robust yet exceedingly handy and easy to use instrument for temperature measuring in hazardous areas.

 

The Benefits of Non-Contact Measurement:

  • Increased safety when determining the temperature of fast moving objects.

  • No antennas mean that frictional heat cannot affect the measurement.

  • No mark or blemish is left on the object being measured.

Response Time:

  • Fast and accurate. Pyrometers respond to emitted energy and are around 20 to 1000 times quicker than a traditional direct contact thermometer.

Low Maintenance and Non-Invasive:

  • The temperature of the object being measured is not affected by the procedure.

  • Non contact of the detector means no wear and tear.

  • No fixing or fastening points required on either the object or equipment.

Hard To Reach Objects and Moving Materials

  • The optics of the pyrometer are aimed at the object to be measured and with the laser sighting it is possible for both small and distant objects to be targeted.

  • Hazardous and aggressive materials can be safely measured - and without fear of damaging the equipment.

  • The compact size of the pyrometer allows it to be used in even the most awkward positions, with only a clear line of sight to the target area being required.

  • With direct contact measurement, poor heat conduction or heat capacity of the object can prevent insufficient heat flow to a measuring device.

Certifications:

Certification:

II 2 G EEx ia IIC T4

Certificate of Conformity:

TÜV 00 ATEX 1580 X

Class I Zone 0 AEx ia IIC T4
IS Class I Divison 1 Group A-D T4

Intrinsically Safe PDFData Sheet

Intrinsically Safe PDFManual

Intrinsically Safe PDFCertificate

Ordering Information:

 

Visit This Product at www.ReliabilityDirectStore.com for Pricing and Ordering

 

Specifications:

Temperature range:

-18°C … +260°C
(0°F … 500°F)

Display resolution:

0.5°C (1.0 F)

Target sighting:

Laser (class 2)

Accuracy (at 23°C):

-18°C … -1°C ±3°C

0°C … 99°C ±2°C

100°C … +260°C ±2%

± 2°C or ± 2% of reading
whichever is greater

Repeatability:

± 2% of reading or ± 2°C - whichever is greater

Response time:

500 msec

Emissivity:

preset 0.95

Spectral response:

7 to 18 µm

Ambient operating range:

0°C…+50°C

Storage temperature range (without battery):

-20°C … +65°C

Relative humidity:

10 to 95% r.H.
non-condensing at up to 30 deg C

Power supply:

9V alkaline battery
type IEC 6LR61

Dimensions:

~152 x 101 x 38 mm

Weight:

~ 200 g