1-888-710-6786

281-957-5283

Visit our new

all-inclusive e-store:

Home

Terms

Categories New Store

Forums

Links

About

Contact

          

Visit Our New All-Inclusive Store - www.ReliabilityDirectStore.com

Product Categories:

Measurement
Maintenance
Calibration
Flashlights
Data Processing
Communication

Rating Information:

FM
CSA
ATEX
UL
IS

Definitions

 

 

 

Intrinsically-Safe Non-Contact Infrared Thermometer


For non-contact temperature measurement and monitoring of temperature processes in hazardous areas.

  • Temperature range: from -22°F to +1652°F (-30 to +900°C)

  • Quick response time: 250 ms

  • Simple operation: trigger action

  • Trend display: recall of previous 10 readings

  • Reliable: laser circuitry provides measurement mark diameter

  • Measurements: From Zone 1 to Zone 0

Intrinsically Safe Non-Contact Infrared Thermometer

The intrinsically-safe non-contact temperature meter EX-MX2 is a robust, highly reliable and easy to use instrument for measuring the temperature of objects that are difficult to access, are moving or are as material on conveyor belts.

 

Operation could not be simpler: sight the object, press the trigger and the temperature can be read off the display immediately. The need to use the time consuming practice of focusing or calibration is now a thing of the past.

 

The laser sighting allows exact areas - even on distant objects - to be pinpointed, so that high accuracy and an exact capture of a specific area can be guaranteed. The Emissivity-Factor of 0.1 to 1.5 can be variably adjusted by increments of 0.01. This enables high measuring accuracy with only the emitted radiation part of a body being calculated from a cluster of emitted, reflected and transmitted radiation.

Constant information about the actual temperature as well as minimum and maximum temperature values are displayed along with a graphical trend of the previous 10 readings and also the condition of the battery.

 

The back-lighted display enables readings to be taken even when used in dark environments and poor light conditions. The benefit of this simple yet robust device is that temperature monitoring as part of routine maintenance or manufacturing procedures can be easily carried out over a wide temperature range of -22 to + 1652°F (-30°C to +900°C) with an accuracy of + 1.8°F (1°C) (up to 212°F/100°C) and + 1% (above 212°F/100°C).


The EX-MX2 now allows high precision, repeat accuracy of temperature monitoring tasks to be carried out safely within the hazardous area.

Certifications:

Certification:

II 2 G EEx ia IIC T4

Certificate of Conformity:

TÜV 00 ATEX 1597 X

Intrinsically Safe PDFData Sheet

Intrinsically Safe PDFManual

Intrinsically Safe PDFCertificate

Ordering Information:

 

Visit This Product at www.ReliabilityDirectStore.com for Pricing and Ordering

 

Specifications:

Temperature range:

-22°F to 1652°F (-30°C ...+900°C)

Accuracy:
(at ambient 68°F± 86°F)

-22°F… 30.2°F ±3.6°F
32°F … 210.2°F ±1.8°F
212°F … 1652°F ±1% ± 1.8°F or ± 1%
(-30°C … -1°C ±2°C 0°C … 99°C ±1°C 100°C … 900°C±1% ± 1°C or ± 1%) of reading - whichever is greater

Repeatability:

±0.5% or ±1.8°F of reading whichever is greater

Response time: (95%)

250 ms

Indication elimination:

0.2°F (0.1°C) with temperature

Emissivity adjustment:

0.1 to 1.5
(0.01 incremental)

Display:

actual temperature
minimum temperature
maximum temperature
graphical trend
(previous 10 readings)
warning symbol
emissivity level
battery condition

Ambient operating range:

32°F to 122°F (0°C … +50°C)
- with laser max. +113°F

Storage temperature:

-4°F to +113°F (-20°C … +50°C)

Relative humidity:

10-95% r.H.
at up to 86°F

Battery:

IEC LR6/AA
respectively R6/AA

Dimensions:

7.8" x 6.6" x 2" (200 x 170 x 50 mm)

Weight:

approx. 16 oz (450 gr.)

Spectral response:

8 to 14 µm

Laser:

class 2 laser