Intrinsically-Safe Non-Contact Infrared Thermometer


For non-contact temperature measurement and monitoring of temperature processes in hazardous areas.

  • High accuracy

  • Simple operation

  • Quick response time

  • Laser sighting: offset 8 point circular

  • Data logging: 12 points

  • Display resolution: 0.1°C/F

  • Distance to spot (D:S) 50:1

  • External temperature probe

Intrinsically Safe Non-Contact Infrared Thermometer

The intrinsically-safe non-contact temperature measuring equipment ST 80 IS is a robust yet exceedingly handy and easy to use instrument for temperature measuring in hazardous areas.

The benefits of non-contact measurement

  • Increased safety when determining the temperature of fast moving objects.

  • No antennas mean that frictional heat cannot affect the measurement.

  • No mark or blemish is left on the object
    being measured.

Response time

  • Fast and accurate. Pyrometers respond to emitted energy and are around 20 to 1000 times quicker than a traditional direct contact thermometer.

Low maintenance and non-invasive

  • The temperature of the object being measured is not affected by the procedure.

  • Non contact of the detector means no wear and tear.

  • No fixing or fastening points required on either the object or equipment.

Hard to reach objects and moving materials

  • The optics of the pyrometer are aimed at the object to be measured and with the laser sighting it is possible for both small and distant objects to be targeted.

  • Hazardous and aggressive materials can be safely measured - and without fear of damaging the equipment.

  • The compact size of the pyrometer allows it to be used in even the most awkward positions, with only a clear line of sight to the target area being required.

  • With direct contact measurement, poor heat conduction or heat capacity of the object can prevent insufficient heat flow to a measuring device.

Certifications:

I.S. Class I Division 1 Groups A-D T4
Class I Zone 0 AEx ia IIC T4

Intrinsically Safe PDFData Sheet

Intrinsically Safe PDFManual

Intrinsically Safe PDFCertificate

Ordering Information:

 

Visit This Product at www.ReliabilityDirectStore.com for Pricing and Ordering

 

Specifications:

Temperature Range:

-25°F to 1400°F (-32°C to 760°C)

Accuracy ambient operating temperature @ 73°F (23°C):

1% or = +2°F (1°C)
whichever ist greater
above 73°F (23°C)
+3.6°F (2°C) @ 0°F to 73°F
(-18°C to 23°C)
+4.5°F (2.5°C) @ -15°F to 0°F
(-26°C to -18°C)
+5.5°F (3°C) @ -25°F to -15°F
(-32°C to 26°C)

Repeatability:

<0.5% or <1.8°F (= 1°C)
whichever is greater

Response Time:

<0.5 second (95% of reading)

Ambient Operating Range:

32°F to 120°F (0°C to 50° C)

Power:

9V Alkaline of NiCd Battery

Weight:

11 oz (320g)