1-888-710-6786

281-957-5283

Visit our new

all-inclusive e-store:

Home

Terms

Categories New Store

Forums

Links

About

Contact

          

Visit Our New All-Inclusive Store - www.ReliabilityDirectStore.com

Product Categories:

Measurement
Maintenance
Calibration
Flashlights
Data Processing
Communication

Rating Information:

FM
CSA
ATEX
UL
IS

Definitions

 

 

 

Intrinsically-Safe Vibration Pen


Features:

  • Small and Rugged

  • Overall Vibration in terms of Velocity

  • Acceleration Enveloping

  • Temperature Magnet

  • Includes Vibration Severity Chart

  • Programmable Alarms

  • Visible LED Indicators

    • "Green" OK Indication

    • "Amber" 1st Level Alarm Indication

    • "Red" 2nd Level Alarm Indication

  • Programmable English or Metric

Intrinsically Safe Vibration Pen

The SKF MARLIN™ condition detector (MCD) from SKF provides a simple but extremely effective means of checking the health of a machine, measuring vibration and temperature to assess its operating state. By putting MCD into the hand of plant or maintenance personnel, the frequency of checking can be increased, warnings can be received earlier and plant condition experts can be freed to focus only on specific problem areas.

 

Overall Velocity vibration is an excellent measurement parameter for determining rotational and structural problems such as imbalance, misalignment, looseness and stress applied to components. Acceleration Enveloping measures higher frequencies usually associated with bearing problems and gear mesh. Temperature is measured by a unique sensing magnet to detect and signal temperatures values outside of the acceptable range.

Certifications:

Certification:

EEx ia IIc T4

Class I, Division 1,

Groups A, B, C, D T3A

Intrinsically Safe PDFData Sheet

Intrinsically Safe PDFManual

Intrinsically Safe PDFCertificate

Ordering Information:

 

Visit This Product at www.ReliabilityDirectStore.com for Pricing and Ordering

 

Specifications:

Vibration Pickup:

Integrated Piezoelectric Acceleration (Ceramic, Shear Type)

Measurement Range:

Velocity: 0.3 – 55mm/s (RMS), 0.02 – 3.00 in/s (Eq. Peak). Meets ISO Standard 10861-1.

Enveloped Acceleration: 0.3 gE – 20.0 gE.

Temperature: +32°F to +212°F (0°C to +100°C)

Frequency Range:

Overall Velocity: 10 Hz – 1 kHz. (Tolerances measured within the frequency range are in accordance with ISO 3945.)

Acceleration Enveloping Band 3: 500 Hz – 10 kHz.

Display Viewing Area:

2.165" x 0.700" (54.99mm x 17.78mm)

Main Power:

Two (2) 1.5 V alkaline "AA" batteries

Battery Lifetime:

30 hours

Backup Battery:

One (1) 3 V BR1225 Lithium Ion Battery

Auto Off:

Two (2) minute countdown on last operation

Case:

Water and dust resistant (IP 65)

Drop Test:

Six (6) feet on multiple axes

Dimensions:

7.50" (L) x 1.70" (W) x 1.63" (H) [190.5mm (L) x 43.2mm (W) x 41.4mm (H)]

Weight:

0.95 lb (431 gms) with battery, 1.4 lb (635 gms) with temperature magnet probe tip

Operating Temperature:

-4°F to +140°F (-20°C to +60°C)

Storage Temperature:

-34°F to +158°F (-37°C to +70°C)

Humidity:

5 – 95% non-condensing

Communication Port Type:

Micro D RS-232

Baud Rate:

9600